Technical Resource

How to Test Dispersing Power: Standard Methods

Updated Oct 25, 2026

How to Test Dispersing Power: Standard Methods

Dispersing power is how well a dispersant breaks up and keeps particles separated in a liquid. It is measured by comparing a dispersion made with the test sample against one made with a reference sample: through filter tests for dyes, suspensibility tests for agrochemicals, viscosity and particle size for slurries, and fineness of grind for pigment pastes. On data sheets it is often given relative to a standard product, for example “dispersing power 95% min” for Dispersant NNO Grade A.

What “Relative Dispersing Power” Means

Many dispersant specifications express dispersing power as a percentage of a standard sample tested by the same method. A value of 95% means the test sample performs at 95% of the reference. The number is only meaningful with the method and reference, so ask for both when comparing products.

Product (TDS)Dispersing power vs standardSodium sulphate
Dispersant NNO Grade A (GAC-NNO-A)95% min5% max
Dispersant NNO Grade B (GAC-NNO-B)90% min18% max
Typical values from the current Green Agrochem TDS.

Methods by Application

ApplicationMethodStandard or reference
Disperse dyesDouble filter paper test (room temperature and high temperature)GB/T 5540-2017, GB/T 5541-2017; AATCC TM146; ISO 105-Z04
Agrochemical SC and WGSuspensibility, dispersibility, wet sieveCIPAC MT 184.1, MT 174, MT 185.1
Pigment pastes and inksFineness of grind; colour strengthGrindometer (Hegman gauge), ISO 1524; colour strength against a reference
Mineral and ceramic slurriesViscosity at fixed solids vs dispersant dose (deflocculation curve)Rotational viscometer; find the dose at minimum viscosity
Any suspensionParticle size distribution; zeta potentialLaser diffraction (ISO 13320); electrophoretic mobility (ISO 13099)
Cement and concretePaste or mortar flow at fixed water/cement ratioFlow cone or mini-slump; national admixture standards

Building a Reliable Comparison

  • Use the same solid, water and solids content for every sample.
  • Run a dose series, not a single point; dispersants differ in optimum dose.
  • Include the current product as reference in every test run.
  • Test fresh and after storage or heat ageing.
  • Report the method, temperature, water hardness and dose with every result.

Frequently Asked Questions

What does “dispersing power 95%” mean?

That the sample performs at 95% of a standard reference product in the specified test. It is a relative value, valid only for the stated method and reference.

How do you test a dispersant for a ceramic or mineral slurry?

Measure viscosity of a slurry at fixed solids while adding the dispersant step by step. The dose giving minimum viscosity, and the viscosity reached, show its effectiveness.

Which tests are used for dispersants in pesticide formulations?

CIPAC suspensibility (MT 184.1), dispersibility of granules (MT 174) and wet sieve tests (MT 185.1), plus accelerated storage.

References

Questions about a specification, a test method or a trial: contact us or email info@greenagrochem.com.